Standard for Emergency and Standby Power Systems

1.1 Scope. This standard contains requirements covering the performance of emergency and standby power systems providing an alternate source of electrical power to loads in buildings and facilities in the event that the primary power source fails. 1.1.1 Power systems covered in this standard include power sources, transfer equipment, controls, supervisory equipment, and all related electrical and mechanical auxiliary and accessory equipment needed to supply electrical power to the load terminals of the transfer equipment. 1.1.2 This standard covers installation, maintenance, operation, and testing requirements as they pertain to the performance of the emergency power supply system (EPSS). 1.1.3 This standard does not cover the following: (1) Application of the EPSS (2) Emergency lighting unit equipment (3) Distribution wiring (4) Utility service when such service is permitted as the EPSS (5) Parameters for stored energy devices (6) The equipment of systems that are not classed as Level 1 or Level 2 systems in accordance with Chapter 4 of this standard 1.1.4* This standard does not establish criteria for stored energy systems. 1.1.5 The selection of any of the following is not within the scope of this standard: (1) Specific buildings or facilities, or both, requiring an EPSS (2) Specific loads to be served by the EPSS (3)*Assignment of type, class, or level to any specific load

What is NFPA 110?

NFPA 110, also known as the Standard for Emergency and Standby Power Systems, is a document published by the National Fire Protection Association (NFPA) that provides guidelines and requirements for the proper installation and maintenance of emergency and standby power systems.

These systems are essential for ensuring the safety and functionality of critical infrastructure, such as hospitals, airports, and data centers, in the event of a power outage or other emergency.

These power systems include equipment such as generator sets, circuit breaker, transfer switches, control panels, remote equipment, and more.

Emergency power systems are designed to provide temporary power to a facility during an outage or other emergency situation, while standby power systems are intended to provide a continuous source of power in the event of a primary power loss.

Both types of systems are essential for ensuring the safety and functionality of critical infrastructure, as well as protecting the people and property within those facilities.

According to NFPA 110, all emergency and standby power systems must be properly sized and installed to meet the specific needs of the facility where they are being used. This includes taking into account the potential load on the system, as well as the duration and frequency of power outages in the area.

In addition, the standard requires that these systems be tested regularly to ensure they are functioning properly and can provide the necessary power when needed.

NFPA 110 is updated every three years, with the latest revisions being published in 2022. These frequent updates keep the standards up-to-date and reflecting the latest technologies used in emergency and standby power systems.

Technician working on an outdoor genset

 

The Importance of Maintenance and Regular Testing

One of the key components of NFPA 110 is the requirement for regular maintenance and testing of emergency and standby power systems.

This includes periodic inspections and annual testing of the system itself, regular maintenance of the equipment that make up the system, as well as the proper handling and storage of fuel for these systems.

This is essential for ensuring that the system is able to provide power when needed, as well as for identifying and addressing any potential issues before they become major problems.

Fire safety technician working with a fire prevention system

Fuel testing is an important part of ensuring the smooth operation of mission critical facilities. These facilities rely on a steady supply of fuel to power their critical systems and keep them running.

Without regular fuel testing, it is difficult to know if the fuel being used is of the right quality and composition, and this can lead to a number of problems.

Over time, fuel can degrade and lose some of its key properties, such as its ability to burn cleanly and efficiently. This can lead to reduced power output, increased emissions, and damage to critical equipment.

Critical component damage can render the system inoperable, which can seriously impact the facilities relying on these emergency power systems.

By regularly testing the fuel, it is possible to detect and remove any contaminants before they cause any problems, helping to ensure that the facility can continue to operate at peak efficiency.

Maintaining Mission Critical Reliability

The importance of NFPA 110 lies in its ability to help protect against the potential dangers of power outages and other emergency situations.

In a hospital, for example, the loss of power could have serious consequences for patients who rely on life-support equipment. In a data center, a power outage could cause the loss of valuable data and disrupt critical operations.

By setting minimum requirements for the design, installation, maintenance, and testing of emergency and standby power systems, NFPA 110 helps to ensure that these systems are reliable and capable of providing power when needed.

Overall, NFPA is a crucial standard for ensuring the reliability and safety of emergency and standby power systems.

By following the requirements of the standard, facilities can protect critical equipment and maintain essential services in the event of a power outage or other emergency.